Detcon Product Guide | ||
Table of Contents | ||
Description | Page | |
Gas Detection Sensors | 3 | |
1.1 | Model Series 700 Gas Detection Sensor Assemblies | 3 |
1.2 | Model Series 600 MicroSafe Gas Detection Sensor Assemblies | 8 |
1.3 | Model Series 500 MicroSafe Gas Detection Sensor Assemblies | 14 |
1.4 | Model Series 400 Gas Detection Sensor Assemblies | 19 |
1.5 | Model Series 100 Low Power Gas Detection Sensor Assemblies | 20 |
1.6 | Detcon Sample Draw Manifold Assemblies | 23 |
1.7 | Fire Detection Sensor Assemblies | 24 |
2 | Gas Detection Control Systems | 25 |
2.1 | Model Series 10 Single Control Card Gas Detection Control Systems | 25 |
2.2 | Model Series 12 Single Control Card Gas Detection Control Systems | 27 |
2.3 | Model Series X40 Multi-Channel Gas Detection Control Systems | 29 |
2.4 | Model Series MCX-32 Multi-Channel Gas Detection Control Systems | 31 |
2.5 | Model 880A/S PLC Graphic Gas Detection Control Systems | 32 |
2.6 | Remote Displays | 33 |
3 | Gas Detection System Accessory Circuits | 34 |
4 | Power Supplies and Stand-by Battery Systems | 35 |
5 | Gas Detection Calibration Kits and Span Gas Cylinders | 36 |
6 | Special Application Products | 38 |
7 | Process Gas Analyzers | 39 |
Audio Visual Alarm Stations | 44 | |
9 | SmartWireless™ Technology | 48 |
Page 2 | ||
Section 1.0 Gas Detection Sensor Assemblies | ||
Section 1.1 Model Series 700 Gas Detection Sensors (Does not include junction box. | ||
See section 1.1.7 for junction box adder instructions.) | ||
1.1.1 Combustible Gas Detection Sensor Assemblies | ||
Part Number | Model Number - Description | |
967-525520-100 | FP-700 Catalytic Combustible Gas Sensor Assembly | |
967-215520-100 | IR-700-CH Infrared Combustible Hydrocarbon Sensor Assembly | |
1.1.2 Hydrogen Sulfide Gas Detection Sensor Assemblies | ||
Part Number | Model Number - Description | |
967-015520-100 | TP-700 Solid State MOS H2S Sensor Assembly | |
967-242490-100 | DM-700-H2S Electro Chemical H2S Sensor Assembly | |
1.1.3 Oxygen Gas Detection Sensor Assemblies | ||
Part Number | Model Number - Description | |
967-345520-025 | DM-700-O2 Oxygen Deficiency Sensor Assembly | |
1.1.4 VOC Gas Detection Sensor Assemblies | ||
Part Number | Model Number - Description | |
967-P15520-010 | PI-700-VOC Volatile Organic Compound Sensor Assembly | |
967-P25520-01K | PI-701-VOC Volatile Organic Compound Sensor Assembly | |
1.1.5 Carbon Dioxide Gas Detection Sensor Assemblies | ||
Part Number | Model Number - Description | |
967-405520-005 | IR-700-CO2 Infrared Sensor Assembly - Low Range (0-5%) | |
967-425520-025 | IR-700-CO2 Infrared Sensor Assembly - High Range (10-100%) | |
1.1.6 Electrochemical Toxic Gas Detection Sensor Assemblies | ||
Standard Range is indicated by the last 3 digits of the part number. Contact the Detcon factory for other ranges. | ||
Part Number | Model Number - Description | |
967-12EA90-100 | DM-700-C2H3O Acetyldehyde Sensor Assembly | |
967-12EG90-100 | DM-700-C2H2 Acetylene Sensor Assembly | |
967-12EM90-100 | DM-700-C3H3N Acrylonitrile Sensor Assembly | |
967-505090-100 | DM-702-NH3 Ammonia Sensor Assembly | |
967-191990-001 | DM-700-AsH3 Arsine Sensor Assembly | |
967-747590-005 | DM-700-Br2 Bromine Sensor Assembly | |
967-12EB90-100 | DM-700-C4H6 Butadiene Sensor Assembly | |
967-444490-100 | DM-700-CO Carbon Monoxide Sensor Assembly | |
967-747490-010 | DM-700-CL2 Chlorine Sensor Assembly | |
967-777790-001 | DM-701-CLO2 Chlorine Dioxide Sensor Assembly (0-1ppm) | |
967-747690-050 | DM-700-CLO2 Chlorine Dioxide Sensor Assembly (0-50ppm) | |
967-192190-005 | DM-700-B2H6 Diborane Sensor Assembly | |
967-12EO90-100 | DM-700-C2H5OH Ethanol Sensor Assembly | |
967-24EZ90-100 | DM-700-C2H5SH Ethyl Mercaptans Sensor Assembly | |
967-12ED90-100 | DM-700-C2H4 Ethylene Sensor Assembly | |
967-12EJ90-100 | DM-700-C2H4O Ethylene Oxide Sensor Assembly | |
967-272790-001 | DM-700-F2 Fluorine Sensor Assembly | |
967-12EP90-100 | DM-700-CH2O Formaldehyde Sensor Assembly | |
Page 3 | ||
967-232590-002 | DM-700-GeH4 Germane Sensor Assembly | |
967-262690-001 | DM-700-N2H4 Hydrazine Sensor Assembly | |
967-848490-100 | DM-700-H2 Hydrogen Sensor Assembly (ppm Range) | |
967-050590-04P | DM-701-H2 Hydrogen Sensor Assembly (4% Range) | |
967-070790-01P | DM-702-H2 Hydrogen Sensor Assembly (1% Range) | |
967-090890-030 | DM-700-HBr Hydrogen Bromide Sensor Assembly | |
967-090990-030 | DM-700-HCL Hydrogen Chloride Sensor Assembly | |
967-131390-030 | DM-700-HCN Hydrogen Cyanide Sensor Assembly | |
967-333390-010 | DM-700-HF Hydrogen Fluoride Sensor Assembly | |
967-242490-100 | DM-700-H2S Hydrogen Sulfide Sensor Assembly | |
967-12EE90-100 | DM-700-CH3OH Methanol Sensor Assembly | |
967-24EK90-100 | DM-700-CH3SH Methyl Mercaptans Sensor Assembly | |
967-949490-100 | DM-700-NO Nitric Oxide Sensor Assembly | |
967-646490-010 | DM-700-NO2 Nitrogen Dioxide Sensor Assembly | |
967-393990-001 | DM-700-O3 Ozone Sensor Assembly | |
967-414190-001 | DM-700-COCL2 Phosgene Sensor Assembly | |
967-192090-005 | DM-700-PH3 Phosphine Sensor Assembly | |
967-232390-050 | DM-700-SiH4 Silane Sensor Assembly | |
967-555590-020 | DM-700-SO2 Sulfur Dioxide Sensor Assembly | |
967-12EF90-100 | DM-700-C4H6O2 Vinyl Acetate Sensor Assembly | |
967-12EL90-100 | DM-700-C2H3CL Vinyl Chloride Sensor Assembly | |
1.1.7 Model Series 700 Junction Box Adder | ||
Todetectionorder asensormodelwith700 agas | ||
junctionpart numberbox,ofmodifythe sensorthe | ||
(s)theyouinstructionswant accordingbelow. to | ||
Catalytic Combustible, Solid State H2S, Oxygen, VOC, & CO2 | ||
With aluminum junction box, indicate a "1" in position 6 of the PN (xxx-xx1xxx-xxx) | ||
With stainless steel junction box, indicate a "4" in position 6 of the PN (xxx-xx4xxx-xxx) | ||
Electrochemical: NOTE: Detcon recommends selection of the 316SS J-box for strong | ||
acid gas compounds (HCl, Cl2, Br2, F2, HBr, HF) | ||
With aluminum junction box, indicate a "1" in position 9 of the PN (xxx-xxxxx1-xxx) | ||
With stainless steel junction box, indicate a "4" in position 9 of the PN (xxx-xxxxx4-xxx) | 6 | |
Page 4 | ||
1.1.8 Model Series 700 Integration Modules | ||
Part Number | Model Number - Description | |
975-70000A-00A | Remote Control / Alarm Relay Module in Aluminum Enclosure Class | |
1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
975-70000A-00S | Remote Control / Alarm Relay Module in 316SS Enclosure | |
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
975-70000H-00A | Remote Control / Alarm Relay Module with Hart in Aluminum | |
Enclosure Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
975-70000H-00S | Remote Control / Alarm Relay Module with Hart in 316SS Enclosure | |
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
975-70000P-00A | Remote Control / Alarm Relay Module with Profibus in Aluminum | |
Enclosure Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
975-70000P-00S | Remote Control / Alarm Relay Module with Profibus in 316SS | |
Enclosure Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
975-70000F-00A | Remote Control / Alarm Relay Module with Foundation Fieldbus in | |
Aluminum Enclosure Class 1; Div 1; Groups B, C, D – Zone I Group | ||
975-70000F-00S | Remote Control / Alarm Relay Module with Foundation Fieldbus in | |
316SS Enclosure Class 1; Div 1; Groups B, C, D – Zone I Group | ||
975-70005H-00A | Hart Integration Module in Aluminum Enclosure | |
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
975-70005H-00S | Hart Integration Module in 316SS Enclosure | |
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
975-70005P-00A | Profibus Integration Module in Aluminum Enclosure | |
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
975-70005P-00S | Profibus Integration Module in 316SS Enclosure | |
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
975-70005F-00A | Foundation Fieldbus Integration Module in Aluminum Enclosure | |
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
975-70005F-00S | Foundation Fieldbus Module in 316SS Enclosure | |
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
976-000321-000 | Wireless Integration RXT 320 in Aluminum Enclosure | |
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
976-000322-000 | Wireless Integration RXT 320 in 316SS Enclosure | |
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2 | ||
1.1.9 Model Series 700 Spare Parts - Universal | ||
Part Number | Model Number - Description | |
613-120000-700 | Sensor splash guard with integral cal-port | |
327-000000-000 | Magnetic programming tool | |
975-000020-893 | Sensor duct mount kit – 700 Series | |
960-202200-000 | Condensation prevention packet (for J-Box replace annually) | |
500-003087-100 | Transient Protection Module | |
437-500000-000 | Stainless steel tag | |
943-004223-000 | 2" pipe mount with sun shade | |
943-004221-000 | Sensor Mounting Plate for 2" pipe | |
897-850000-010 | Standard aluminum junction box with solid lid | |
897-850901-010 | Standard aluminum junction box with lens cover | |
897-850000-316 | Stainless steel junction box with solid cover | |
897-850901-316 | Stainless steel junction box with lens cover | |
943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) | |
033-003238-000 | Harsh location dust guard replacement filter | |
Page 5 | ||
943-003436-000 | Harsh location water guard | |
943-000000-000 | Calibration Sleeve/Wind Guard for use with splash guard | |
943-001747-SS5 | Stainless steel flow through adapter | |
1.1.10 Spare Parts - FP-700 Catalytic Combustible Gas Sensor Assembly | ||
Part Number | Model Number - Description | |
927-525500-100 | FP-700 Catalytic Combustible Gas (ITM) | |
602-003152-000 | Bottom housing assembly for FP/TP/IR - includes flame arrestor | |
370-201600-700 | Combustible Gas plug-in sensor for FP-700 | |
1.1.11 Spare Parts - IR-700-CH Infrared Combustible Hydrocarbon Sensor Assembly | ||
Part Number | Model Number - Description | |
927-215500-100 | IR-700-CH Infrared Combustible Hydrocarbon (ITM) | |
602-003152-000 | Bottom housing assembly for FP/TP/IR - includes flame arrestor | |
370-3658CH-700 | Combustible Hydrocarbon plug-in sensor for IR-700-CH | |
1.1.12 Spare Parts - TP-700 Solid State MOS H2S Sensor Assembly | ||
Part Number | Model Number - Description | |
927-015500-100 | TP-700 Solid State MOS H2S (ITM) | |
602-003152-000 | Bottom housing assembly for FP/TP/IR - includes flame arrestor | |
370-010000-700 | Solid State MOS H2S plug-in sensor for TP-700 | |
1.1.13 Spare Parts - DM-700-H2S Electro Chemical H2S Sensor Assembly | ||
Part Number | Model Number - Description | |
927-245500-000 | DM-700-EC Electro Chemical Universal ITM | |
600-003215-000 | Splash guard adapter for DM/O2/PI | |
377-242400-100 | Hydrogen Sulfide plug-in sensor for DM-700-H2S | |
1.1.14 Spare Parts - DM-700-O2 Oxygen Deficiency Sensor Assembly | ||
Part Number | Model Number - Description | |
927-345500-025 | DM-700-O2 Oxygen Deficiency (ITM) | |
600-003215-000 | Splash guard adapter for DM/O2/PI | |
377-343400-025 | Oxygen plug-in sensor for DM-700-O2 | |
1.1.15 Spare Parts - PI-700-VOC Volatile Organic Compound Sensor Assembly | ||
Part Number | Model Number - Description | |
927-P25500-000 | PI-700 Volatile Organic Compound (ITM) Universal | |
600-003215-000 | Splash guard adapter for DM/O2/PI | |
377-P10000-010 | Photo Ionization plug-in sensor for PI-700-10 (0-10ppm) | |
377-P20000-01K | Photo Ionization plug-in sensor for PI-701-1K (0-1000ppm) | |
602-003295-FLT | PI-700 Splash guard adapter assembly with filter | |
1.1.16 Spare Parts - IR-700-CO2 Infrared Sensor Assembly | ||
927-405500-000 | IR-700-CO2 Infrared Carbn Dioxide ( ITM ) Low range ( 0-5%) | |
927-425500-000 | IR-700-CO2 Infrared Carbn Dioxide ( ITM ) High range ( 10-100%) | |
602-003152-000 | Bottom housing assembly for FP/TP/IR - includes flame arrestor | |
370-365878-700 | Carbon Dioxide plug-in sensor for IR-700-CO2 (0-5%) | |
370-287724-700 | Carbon Dioxide plug-in sensor for IR-700-CO2 (10-100%) | |
Page 6 | ||
1.1.17 Spare Parts - DM-700 Electrochemical Toxic Gas Sensor Assemblies | ||
Part Number | Model Number - Description | |
927-245500-000 | DM-700-EC Electro Chemical Universal ITM | |
600-003215-000 | Splash guard adapter for DM/O2/PI | |
377-12EA01-100 | Acetyldehyde plug-in sensor for DM-700-C2H3O | |
377-12EG01 -100 | Acetylene plug-in sensor for DM-700-C2H2 | |
377-12EM01-100 | Acrylonitrile plug-in sensor for DM-700-C3H3N | |
377-505001-100 | Ammonia plug-in sensor for DM-702-NH3 | |
377-191901-001 | Arsine plug-in sensor for DM-700-AsH3 | |
377-747501-005 | Bromine plug-in sensor for DM-700-Br2 | |
377-12EB01-100 | Butadiene plug-in sensor for DM-700-C4H6 | |
377-444401-100 | Carbon Monoxide plug-in sensor for DM-700-CO | |
377-747401-010 | Chlorine plug-in sensor for DM-700-CL2 | |
377-777701-001 | Chlorine Dioxide plug-in sensor for DM-700-CLO2 (0-1ppm) | |
377-747601-050 | Chlorine Dioxide plug-in sensor for DM-700-CLO2 (0-50ppm) | |
377-192101-005 | Diborane plug-in sensor for DM-700-B2H6 | |
377-12EO01-100 | Ethanol plug-in sensor for DM-700-C2H5OH | |
377-24EZ01-100 | Ethyl Mercaptan plug-in sensor for DM-700-C2H5SH | |
377-12ED01-100 | Ethylene plug-in sensor for DM-700-C2H4 | |
377-12EJ01-100 | Ethylene Oxide plug-in sensor for DM-700-C2H4O | |
377-272701-001 | Fluorine plug-in sensor for DM-700-F2 | |
377-12EP01-100 | Formaldehyde plug-in sensor for DM-700-CH2O | |
377-232501-002 | Germane plug-in sensor for DM-700-GeH4 | |
377-262601-001 | Hydrazine plug-in sensor for DM-700-N2H4 | |
377-848401-100 | Hydrogen plug-in sensor for DM-700-H2 (ppm range) | |
377-050501-04P | Hydrogen plug-in sensor for DM-700-H2 (1% & 4% range) | |
377-090801-030 | Hydrogen Bromide plug-in sensor for DM-700-HBr | |
377-090901-030 | Hydrogen Chloride plug-in sensor for DM-700-HCL | |
377-131301-030 | Hydrogen Cyanide plug-in sensor for DM-700-HCN | |
377-333301-010 | Hydrogen Fluoride plug-in sensor for DM-700-HF | |
377-242401-100 | Hydrogen Sulfide plug-in sensor for DM-700-H2S | |
377-12EE01-100 | Methanol plug-in sensor for DM-700-CH3OH | |
377-12EK01-100 | Methyl Mercaptan plug-in sensor for DM-700-CH3SH | |
377-949401-100 | Nitric Oxide plug-in sensor for DM-700-NO | |
377-646401-010 | Nitrogen Dioxide plug-in sensor for DM-700-NO2 | |
377-393901-001 | Ozone plug-in sensor for DM-700-O3 | |
377-414101-001 | Phosgene plug-in sensor for DM-700-COCL2 | |
377-192001-005 | Phosphine plug-in sensor for DM-700-PH3 | |
377-232301-050 | Silane plug-in sensor for DM-700-SiH4 | |
377-555501-020 | Sulfur Dioxide plug-in sensor for DM-700-SO2 | |
377-12EF01-100 | Vinyl Acetate plug-in sensor for DM-700-C4H6O2 | |
377-12EL01-100 | Vinyl Chloride plug-in sensor for DM-700-C2H3CL | |
Page 7 | ||
Section 1.2 Model Series 600 MicroSafe Gas Detection Sensors | ||
1.2.1 Combustible Gas Detection Sensor Assemblies | ||
Part Number | Model Number - Description | |
966-524520-100 | FP-624C Catalytic Combustible Gas Sensor Assembly | |
966-224520-100 | IR-622 Infrared Combustible Hydrocarbon Sensor Assembly | |
Standard range for IR combustible hydrocarbon is 100% LEL. Contact the Detcon factory for other ranges. | ||
1.2.2 Hydrogen Sulfide Gas Detection Sensor Assemblies | ||
Part Number | Model Number - Description | |
966-014520-100 | TP-624D Solid State MOS H2S Sensor Assembly | |
966-01452B-100 | TP-624D-316SS Solid State MOS H2S Sensor Assembly | |
966-242480-100 | DM-600IS-H2S Sensor Assembly | |
1.2.3 Oxygen Gas Detection Sensor Assemblies | ||
Part Number | Model Number - Description | |
966-344520-025 | DM-634 Oxygen Gas Sensor Assembly | |
1.2.4 VOC Gas Detection Sensor Assemblies | ||
Part Number | Model Number - Description | |
966-P14520-010 | PI-600-VOC Sensor Assembly 0-10 PPM | |
966-P24520-01K | PI-601-VOC Sensor Assembly 0-1000 PPM | |
1.2.5 Carbon Dioxide Gas Detection Sensor Assemblies | ||
Part Number | Model Number - Description | |
966-404520-005 | IR-640 Infrared Carbon Dioxide Sensor Assembly (range 0-5%) | |
966-424520-100 | IR-642 Infrared Carbon Dioxide Sensor Assembly (range 10-100%) | |
Contact the Detcon factory for other ranges. | ||
1.2.6 Electrochemical Toxic Gas Detection Sensor Assemblies | ||
Standard Range is indicated by the last 3 digits of the part number. Contact the Detcon factory for other ranges. | ||
Note: Detcon recommends selection of the 316SS J-box for strong acid gas compounds (HCl, Cl2, Br2, F2, HBr, HF) | ||
Part Number | Model Number - Description | |
966-12EA80-100 | DM-600IS-C2H3O Acetyldehyde Sensor Assembly | |
966-12EG80-100 | DM-600IS-C2H2 Acetylene Sensor Assembly | |
966-12EM80-100 | DM-600IS-C3H3N Acrylonitrile Sensor Assembly | |
966-505080-100 | DM-602IS-NH3 Ammonia Sensor Assembly | |
966-191980-001 | DM-600IS-AsH3 Arsine Sensor Assembly | |
966-747580-005 | DM-600IS-Br2 Bromine Sensor Assembly | |
966-12EB80-100 | DM-600IS-C4H6 Butadiene Sensor Assembly | |
966-444480-100 | DM-600IS-CO Carbon Monoxide Sensor Assembly | |
966-747480-010 | DM-600IS-CL2 Chlorine Sensor Assembly | |
966-777780-001 | DM-601IS-CLO2 Chlorine Dioxide Sensor Assembly (0-1ppm) | |
966-747680-050 | DM-600IS-CLO2 Chlorine Dioxide Sensor Assembly (0-50ppm) | |
966-192180-005 | DM-600IS-B2H6 Diborane Sensor Assembly | |
966-12EO80-100 | DM-600IS-C2H5OH Ethanol Sensor Assembly | |
966-24EZ80-100 | DM-600IS-C2H5SH Ethyl Mercaptans Sensor Assembly | |
966-12ED80-100 | DM-600IS-C2H4 Ethylene Sensor Assembly | |
966-12EJ80-100 | DM-600IS-C2H4O Ethylene Oxide Sensor Assembly | |
966-272780-001 | DM-600IS-F2 Fluorine Sensor Assembly | |
966-12EP80-100 | DM-600IS-CH2O Formaldehyde Sensor Assembly | |
966-232580-002 | DM-600IS-GeH4 Germane Sensor Assembly | |
Page 8 | ||
966-262680-001 | DM-600IS-N2H4 Hydrazine Sensor Assembly | |
966-848480-100 | DM-600IS-H2 Hydrogen Sensor Assembly (ppm Range) | |
966-050580-04P | DM-601IS-H2 Hydrogen Sensor Assembly (% Range) | |
966-070780-01P | DM-602IS-H2 Hydrogen Sensor Assembly (1% Range) | |
966-090880-030 | DM-600IS-HBr Hydrogen Bromide Sensor Assembly | |
966-090980-030 | DM-600IS-HCL Hydrogen Chloride Sensor Assembly | |
966-131380-030 | DM-600IS-HCN Hydrogen Cyanide Sensor Assembly | |
966-333380-010 | DM-600IS-HF Hydrogen Fluoride Sensor Assembly | |
966-242480-100 | DM-600IS-H2S Hydrogen Sulfide Sensor Assembly | |
966-12EE80-100 | DM-600IS-CH3OH Methanol Sensor Assembly | |
966-24EK80-100 | DM-600IS-CH3SH Methyl Mercaptans Sensor Assembly | |
966-949480-100 | DM-600IS-NO Nitric Oxide Sensor Assembly | |
966-646480-010 | DM-600IS-NO2 Nitrogen Dioxide Sensor Assembly | |
966-393980-001 | DM-600IS-O3 Ozone Sensor Assembly | |
966-414180-001 | DM-600IS-COCL2 Phosgene Sensor Assembly | |
966-192080-005 | DM-600IS-PH3 Phosphine Sensor Assembly | |
966-232380-050 | DM-600IS-SiH4 Silane Sensor Assembly | |
966-555580-020 | DM-600IS-SO2 Sulfur Dioxide Sensor Assembly | |
966-12EF80-100 | DM-600IS-C4H6O2 Vinyl Acetate Sensor Assembly | |
966-12EL80-100 | DM-600IS-C2H3CL Vinyl Chloride Sensor Assembly | |
1.2.7 Model Series 600 Spare Parts - Universal | ||
Part Number | Model Number - Description | |
327-000000-000 | Magnetic programming tool | |
960-202200-000 | Condensation prevention packet (for J-Box replace annually) | |
437-500000-000 | Stainless steel tag | |
943-004223-000 | 2" pipe mount with sun shade | |
943-004221-000 | Sensor Mounting Plate for 2" pipe | |
975-225007-006 | Remote sensor Jbox, aluminum, 6 wire terminal strip | |
975-316007-006 | Remote sensor Jbox, 316 stainless steel, 6 wire terminal strip | |
897-850000-010 | Standard aluminum junction box with solid lid | |
897-850901-010 | Standard aluminum junction box with lens cover | |
897-850000-316 | Standard 316SS junction box with solid lid | |
897-850901-316 | Standard 316SS junction box with lens cover | |
943-003436-000 | Harsh location water guard | |
943-000000-000 | Calibration Sleeve/Wind Guard for use with splash guard | |
1.2.8 Spare Parts - FP-624C Catalytic Combustible Gas Sensor Assembly | ||
Part Number | Model Number - Description | |
370-201600-000 | Combustible gas field replaceable plug-in sensor | |
926-525500-100 | Plug-in transmitter module (Model FP-624C) | |
500-001794-004 | Standard connector board Model series 600 sensors | |
612-820000-000 | Stainless steel LEL sensor housing with threaded insert | |
399-602016-000 | Stainless steel LEL sensor housings including plug-in sensor | |
613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR | |
943-000006-132 | Calibration adapter FP/IR/DM/O2 | |
975-RSFP00-624 | FP-624 remote sensor separation kit | |
975-000020-890 | Sensor Duct Mount Kit LEL | |
612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR | |
943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) | |
033-003238-000 | Harsh location dust guard replacement filter | |
Page 9 | ||
1.2.9 Spare Parts - IR-622-CH Infrared Combustible Hydrocarbon Sensor Assembly | ||
Part Number | Model Number - Description | |
370-365871-212 | Combustible Hydrocarbon plug-in optical sensor for CH’s | |
926-225500-100 | Plug-in transmitter control module (Model IR-622) | |
500-002042-000 | Standard connector board Model series 600 IR sensors | |
390-000087-000 | Stainless steel sensor housing assembly CH’s | |
613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR | |
943-000006-132 | Calibration adapter FP/IR/DM/O2 | |
975-RSIR00-622 | IR-622 remote sensor separation kit | |
975-000208-9IR | Sensor Duct Mount Kit IR | |
612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR | |
943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) | |
033-003238-000 | Harsh location dust guard replacement filter | |
1.2.10 Spare Parts - TP-624D Solid State MOS H2S Sensor Assembly | ||
Part Number | Model Number - Description | |
399-800000-000 | Solid State MOS H2S Sensor in Stainless Steel Housing | |
926-0155D0-100 | Plug-in transmitter control module (Model TP-624D) | |
500-001794-004 | Standard connector board Model series 600 sensors | |
600-610000-000 | Sensor splash guard w/integral cal port TP-424/TP-524/TP-624 | |
943-000006-038 | Calibration adapter TP | |
326-000000-000 | Replaceable sintered stainless steel flame arrestor | |
975-RSTP00-624 | TP-624 remote sensor separation kit | |
975-000020-891 | Sensor Duct Mount Kit TP | |
943-002274-000 | Harsh location dust guard (fits 7/8 x 14 thread) | |
033-003236-000 | Harsh location dust guard replacement filter | |
1.2.11 Spare Parts - DM-600-H2S Electro Chemical H2S Sensor Assembly | ||
Part Number | Model Number - Description | |
394-242400-xxx* | Intrinsically Safe sensor housing w/preamp circuit *Specify range | |
926-995580-000 | Universal plug-in transmitter control module (DM-600IS) | |
500-001794-004 | Standard connector board Model series 600 sensors | |
613-002646-000 | Sensor splash guard with twist lock adapter | |
975-RSDM00-600 | DM-600 remote sensor separation kit | |
975-000020-892 | Sensor Duct Mount Kit – DM Series | |
370-242400-000 | Hydrogen Sulfide plug-in detector assembly | |
943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) | |
033-003238-000 | Harsh location dust guard replacement filter | |
Page 10 | ||
1.2.12 Spare Parts - DM-600-O2 Oxygen Deficiency Sensor Assembly | ||
Part Number | Model Number - Description | |
370-399100-000 | Oxygen field replaceable plug-in sensor 400/500/600 series | |
926-345500-025 | Plug-in transmitter control module (Model DM-634) | |
500-001794-004 | Standard connector board Model series 600 sensors | |
399-200000-000 | Stainless steel sensor housing with insert and flame arrestor | |
613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR | |
943-000006-132 | Calibration adapter FP/IR/DM/O2 | |
330-X50000-000 | Field Replaceable sintered stainless steel flame arrestor | |
975-RSDM00-634 | DM-634 remote sensor separation kit | |
975-000020-892 | Sensor Duct Mount Kit – DM Series | |
612-400000-000 | Sensor/Sintered Filter replacement wrench FP/DM/IR | |
943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) | |
033-003238-000 | Harsh location dust guard replacement filter | |
1.2.13 Spare Parts - PI-600-VOC Volatile Organic Compound Sensor Assembly | ||
Part Number | Model Number - Description | |
370-P10000-000 | Photo Ionization field replaceable plug-in detector 0-10 PPM | |
370-P20000-000 | Photo Ionization field replaceable plug-in detector 0-1000 PPM | |
926-P16480-010 | Plug-in transmitter control module (Model PI-600/PI-601) | |
500-001794-004 | Standard connector board Model series 600 sensors | |
390-404142-010 | PID sensor housing assembly 10 ppm | |
390-404142-01K | PID sensor housing assembly 1000 ppm | |
613-120000-700 | Sensor splash guard with integral cal-port - FP/DM/IR | |
943-000006-132 | Calibration adapter FP/IR/DM/O2 | |
330-X50000-000 | Field replaceable sintered stainless steel flame arrestor | |
975-600020-000 | PID 10.6eV replacement lamp | |
975-600100-000 | PID detector replacement cell | |
975-520040-000 | PID lamp cleaning kit | |
975-RSPI00-600 | PI-600 remote sensor separation kit | |
975-000208-9IR | Sensor Duct Mount Kit IR | |
943-002273-000 | Harsh location dust guard (fits 1.5 x 18 thread) | |
033-003238-000 | Harsh location dust guard replacement filter | |
1.2.14 Spare Parts - IR-640-CO2 Infrared Sensor Assembly | ||
Part Number | Model Number - Description | |
370-365878-111 | Carbon Dioxide plug-in optical sensor (up to 5% range) | |
370-287724-232 | Carbon Dioxide plug-in optical sensor (10 to 100% range) | |
926-405500-003 | Plug-in transmitter control module (Model IR-640) | |
500-002042-000 | Standard connector board Model series 600 IR s |