Hãng sản xuất | LPS |
Aerosol:
Brush off loose rust and apply to clean, dry surface. Polished surfaces do not provide a good anchor for the product. The surface should be
roughened with a wire brush prior to applying the product. Shake can vigorously until ball inside moves freely. Spray with a sweeping motion
with nozzle about one foot from surface. Dries to touch in 3 to 5 minutes in ambient conditons. Several thin coats at 6 hours intervals provide
greater protection than one heavy application. To avoid clogging, turn can upside down after each use and spray a few short bursts.
Bulk Mixing Instructions:
• Shake can or stir to assure blending of contents.
• Dilute contents with 10 to 20% (1 to 2 pints per gallon) by volume Xylene or Toluene for spraying, dipping or brushing. In VOC regulated
areas, bulk can be diluted with 10 to 20% (1 to 2 pints per gallon) by volume Acetone if required.
• Mix well before, and during application to keep zinc in suspension.
• Apply to cleaned surface using overlapping strokes, making certain that all areas are completely covered.
• For greater protection, apply several thin coats allowing for adequate flash time between coats.
• Clean spray equipment thoroughly with undiluted Xylene, Toluene or Acetone.
Apply Cold Galvanize with temperatures above 45°F (7°C), you must monitor both the surface temperature of the metal and the dew point.
The surface temperature must be at least 5 degrees greater than the dew point. UNDER NO CIRCUMSTANCES IS COLD GALVANIZE TO BE
APPLIED TO WET OR DAMP SURFACES; POOR ADHESION AND ULTIMATE COATING FAILURE WILL RESULT.
Temperature range °F (°C) - 40°F – 750°F (- 40°C – 399°C)
ADDITIONAL INFORMATION
Repaint:6 hours air dry; 30 minutes when baked at 350°F (177°C) for 15 minutes
Withstands:Continuous dry heat up to 750°F (401°C); short period heat up to 1000°F (520°C); water temperature up to 212°F (100°C).
HANDLING
DO NOT spray into or around ignition sources. After handling, always wash hands thoroughly with soap and water. Use only with adequate ventilation. DO NOT breathe vapors or spray mists.
STORAGE
Keep container in a cool, well-ventilated area. DO NOT store near sources of ignition (spark or flame). Store below 120°F (49°C).
Aerosol:
Brush off loose rust and apply to clean, dry surface. Polished surfaces do not provide a good anchor for the product. The surface should be
roughened with a wire brush prior to applying the product. Shake can vigorously until ball inside moves freely. Spray with a sweeping motion
with nozzle about one foot from surface. Dries to touch in 3 to 5 minutes in ambient conditons. Several thin coats at 6 hours intervals provide
greater protection than one heavy application. To avoid clogging, turn can upside down after each use and spray a few short bursts.
Bulk Mixing Instructions:
• Shake can or stir to assure blending of contents.
• Dilute contents with 10 to 20% (1 to 2 pints per gallon) by volume Xylene or Toluene for spraying, dipping or brushing. In VOC regulated
areas, bulk can be diluted with 10 to 20% (1 to 2 pints per gallon) by volume Acetone if required.
• Mix well before, and during application to keep zinc in suspension.
• Apply to cleaned surface using overlapping strokes, making certain that all areas are completely covered.
• For greater protection, apply several thin coats allowing for adequate flash time between coats.
• Clean spray equipment thoroughly with undiluted Xylene, Toluene or Acetone.
Apply Cold Galvanize with temperatures above 45°F (7°C), you must monitor both the surface temperature of the metal and the dew point.
The surface temperature must be at least 5 degrees greater than the dew point. UNDER NO CIRCUMSTANCES IS COLD GALVANIZE TO BE
APPLIED TO WET OR DAMP SURFACES; POOR ADHESION AND ULTIMATE COATING FAILURE WILL RESULT.
Temperature range °F (°C) - 40°F – 750°F (- 40°C – 399°C)
ADDITIONAL INFORMATION
Repaint:6 hours air dry; 30 minutes when baked at 350°F (177°C) for 15 minutes
Withstands:Continuous dry heat up to 750°F (401°C); short period heat up to 1000°F (520°C); water temperature up to 212°F (100°C).
HANDLING
DO NOT spray into or around ignition sources. After handling, always wash hands thoroughly with soap and water. Use only with adequate ventilation. DO NOT breathe vapors or spray mists.
STORAGE
Keep container in a cool, well-ventilated area. DO NOT store near sources of ignition (spark or flame). Store below 120°F (49°C).