Hãng sản xuất | TESCOM |
Công suất (VA) | 120000 |
• Low input current distortion – less than 3%
• High input power factor 0.99
• Power walk-in function to achieve progressive rectifier start-up
• Delayed start-up on mains power supply return
The DS 3 LEVEL Battery Care System optimises battery performance, to help extend their working life and ensure that the UPS can deliver its full-rated back-up time when called upon in an emergency.
Battery recharge: DS 3 LEVEL is designed to work with VRLA AGM and GEL lead-acid batteries including open-vented types, in addition to Ni-Cads. Specific management features include:
• One-level recharge to meet the requirements of the most common VRLA AGM batteries
• Two voltage level recharge meeting the IU characteristic
• Restricted charging to reduce electrolyte consumption and extend the life of VRLA batteries
Temperature compensation: to avoid excessive voltage being applied to the batteries in a high ambient
Battery test: to detect performance degradation and predict battery failure.
Deep discharge protection: to prevent the batteries being discharged below a level from which they cannot be recovered (especially when discharged over long periods with very low loads).
Low AC ripple current: from a high-frequency battery charger, to ensure the batteries are not subjected to this damaging element commonly experienced with some other UPS and power supply designs.
Wide input voltage range: from a rectifier that can work down to less than 40% of its nominal supply rating (at half load), removing the need to discharge the batteries
DS 3 LEVEL can be used for a wide range of applications, thanks to its configuration options, flexibility, accessories and performance levels:
• Suitable for powering capacitive loads, for example Blade servers – without any reduction in active power, from 0.9 leading to 0.9 lagging
• Modes of operation include: On-Line, Eco, Smart-Active and Stand-By/Off
• Frequency conversion mode
• Power Share connections for priority-based load shedding when the mains power supply has failed
• Cold-start facility to switch the UPS on even without a mains power supply present
• Extensive back-up time options using battery extension cabinets
• Optional battery cabinet temperature sensor to assist the temperature compensating charger
• Optional battery chargers to optimize recharge times
• Optional dual input supplies
• Optional isolation transformers for Galvanic isolation and neutral connectivity
The DS 3 LEVEL design provides exceptional performance and efficiency levels, within a very compact footprint and overall case design:
• Lowest footprint in its category – 0.26m² for the 20kVA DS 3 LEVEL with internal batteries.
• High efficiency up to 94% – saving up to 35% in dissipated energy in one year compared to a more traditional UPS (91%) resulting in a faster payback period of four years.
• High output power factor which at 0.9pF provides up to 15% more active power compared to a more traditionally sized UPS – providing greater system expansion margin for further load increases.
MODEL
|
DS3L 10
|
DS3L 12
|
DS3L 15
|
DS3L 20
|
DS3L 30
|
DS3L 40
|
DS3L 60
|
DS3L 80
|
DS3L 100
|
DS3L 120
|
DS3L 160
|
DS3L 200
|
INPUT
|
||||||||||||
Voltage
|
380/400/415 VAC 3 Phase + N
|
|||||||||||
Frequency
|
50Hz. / 60Hz.
|
|||||||||||
Frequency range
|
40 – 72Hz.
|
|||||||||||
Power factor
|
0.99
|
1
|
||||||||||
Harmonic current distortion
|
THDI ≤ 3%
|
|||||||||||
BY PASS
|
||||||||||||
Voltage
|
380/400/415 VAC 3 Phase + N
|
|||||||||||
Number of phases
|
3 + N
|
|||||||||||
Voltage range
|
180 – 264 V (selectable)
|
|||||||||||
Frequency
|
50Hz. or 60Hz. (selectable)
|
|||||||||||
Frequency tolerance
|
± %5 (selectable)
|
|||||||||||
OUTPUT
|
||||||||||||
Power (kVA)
|
10
|
12
|
15
|
20
|
30
|
40
|
60
|
80
|
100
|
120
|
160
|
200
|
Power (kW)
|
9
|
10.8
|
13.5
|
18
|
27
|
36
|
54
|
72
|
90
|
108
|
160
|
200
|
Power factor
|
0.9
|
1
|
||||||||||
Number of phases
|
3 + N
|
|||||||||||
Voltage (V)
|
380 – 400 – 415 VAC (selectable)
|
|||||||||||
Static Variation
|
± % 1
|
|||||||||||
Dynamic Variation
|
± % 3
|
|||||||||||
Crest factor
|
3:1
|
|||||||||||
Voltage distortion
|
≤ % 1 Linear load, ≤ % 3 Non-linear load
|
|||||||||||
Frequency
|
50Hz. / 60Hz.
|
|||||||||||
Frequency stability during battery operation
|
% 0.01
|
|||||||||||
Overload protections (0.8 PF)
|
up to 115% for Continuous, 115%-125% for 10 min, 125%-150% for 1 min, 150%-168% for 5 sec
|
|||||||||||
BATTERIES
|
||||||||||||
Type
|
VRLA AGM / GEL
|
|||||||||||
Recharge time
|
6 hours
|
|||||||||||
INSTALLATION
|
||||||||||||
Weight without batteries
|
105
|
110
|
115
|
115
|
135
|
145
|
190
|
200
|
370
|
380
|
450
|
460
|
Dimensions (mm) HxWxD
|
1320x440x850
|
1320x440x850
|
1600x500x850
|
1900x750x855
|
1900x850x1050
|
|||||||
Communication
|
3 sockets for Communication interface/RS232/USB
|
|||||||||||
Temperature range
|
0ºC / +40ºC
|
|||||||||||
Humidity
|
%90 non-condensed
|
|||||||||||
Colour
|
Dark grey RAL 7016
|
|||||||||||
Acoustic noise (1m)
|
< 52 dBA
|
< 48 dBA
|
< 52 dBA
|
< 65 dBA
|
< 50 dBA
|
|||||||
Protection degree
|
IP20
|
|||||||||||
Efficiency
|
up to % 99
|
|||||||||||
Standards
|
Directive EMC 2004 / 108 / CE Electromagnetic Compability Directive
|
|||||||||||
Standards : Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2
|
||||||||||||
in accordance with IEC EN 62040-3 ( Voltage and Frequency Independent) VFI-SS-111
|
• Low input current distortion – less than 3%
• High input power factor 0.99
• Power walk-in function to achieve progressive rectifier start-up
• Delayed start-up on mains power supply return
The DS 3 LEVEL Battery Care System optimises battery performance, to help extend their working life and ensure that the UPS can deliver its full-rated back-up time when called upon in an emergency.
Battery recharge: DS 3 LEVEL is designed to work with VRLA AGM and GEL lead-acid batteries including open-vented types, in addition to Ni-Cads. Specific management features include:
• One-level recharge to meet the requirements of the most common VRLA AGM batteries
• Two voltage level recharge meeting the IU characteristic
• Restricted charging to reduce electrolyte consumption and extend the life of VRLA batteries
Temperature compensation: to avoid excessive voltage being applied to the batteries in a high ambient
Battery test: to detect performance degradation and predict battery failure.
Deep discharge protection: to prevent the batteries being discharged below a level from which they cannot be recovered (especially when discharged over long periods with very low loads).
Low AC ripple current: from a high-frequency battery charger, to ensure the batteries are not subjected to this damaging element commonly experienced with some other UPS and power supply designs.
Wide input voltage range: from a rectifier that can work down to less than 40% of its nominal supply rating (at half load), removing the need to discharge the batteries
DS 3 LEVEL can be used for a wide range of applications, thanks to its configuration options, flexibility, accessories and performance levels:
• Suitable for powering capacitive loads, for example Blade servers – without any reduction in active power, from 0.9 leading to 0.9 lagging
• Modes of operation include: On-Line, Eco, Smart-Active and Stand-By/Off
• Frequency conversion mode
• Power Share connections for priority-based load shedding when the mains power supply has failed
• Cold-start facility to switch the UPS on even without a mains power supply present
• Extensive back-up time options using battery extension cabinets
• Optional battery cabinet temperature sensor to assist the temperature compensating charger
• Optional battery chargers to optimize recharge times
• Optional dual input supplies
• Optional isolation transformers for Galvanic isolation and neutral connectivity
The DS 3 LEVEL design provides exceptional performance and efficiency levels, within a very compact footprint and overall case design:
• Lowest footprint in its category – 0.26m² for the 20kVA DS 3 LEVEL with internal batteries.
• High efficiency up to 94% – saving up to 35% in dissipated energy in one year compared to a more traditional UPS (91%) resulting in a faster payback period of four years.
• High output power factor which at 0.9pF provides up to 15% more active power compared to a more traditionally sized UPS – providing greater system expansion margin for further load increases.
MODEL
|
DS3L 10
|
DS3L 12
|
DS3L 15
|
DS3L 20
|
DS3L 30
|
DS3L 40
|
DS3L 60
|
DS3L 80
|
DS3L 100
|
DS3L 120
|
DS3L 160
|
DS3L 200
|
INPUT
|
||||||||||||
Voltage
|
380/400/415 VAC 3 Phase + N
|
|||||||||||
Frequency
|
50Hz. / 60Hz.
|
|||||||||||
Frequency range
|
40 – 72Hz.
|
|||||||||||
Power factor
|
0.99
|
1
|
||||||||||
Harmonic current distortion
|
THDI ≤ 3%
|
|||||||||||
BY PASS
|
||||||||||||
Voltage
|
380/400/415 VAC 3 Phase + N
|
|||||||||||
Number of phases
|
3 + N
|
|||||||||||
Voltage range
|
180 – 264 V (selectable)
|
|||||||||||
Frequency
|
50Hz. or 60Hz. (selectable)
|
|||||||||||
Frequency tolerance
|
± %5 (selectable)
|
|||||||||||
OUTPUT
|
||||||||||||
Power (kVA)
|
10
|
12
|
15
|
20
|
30
|
40
|
60
|
80
|
100
|
120
|
160
|
200
|
Power (kW)
|
9
|
10.8
|
13.5
|
18
|
27
|
36
|
54
|
72
|
90
|
108
|
160
|
200
|
Power factor
|
0.9
|
1
|
||||||||||
Number of phases
|
3 + N
|
|||||||||||
Voltage (V)
|
380 – 400 – 415 VAC (selectable)
|
|||||||||||
Static Variation
|
± % 1
|
|||||||||||
Dynamic Variation
|
± % 3
|
|||||||||||
Crest factor
|
3:1
|
|||||||||||
Voltage distortion
|
≤ % 1 Linear load, ≤ % 3 Non-linear load
|
|||||||||||
Frequency
|
50Hz. / 60Hz.
|
|||||||||||
Frequency stability during battery operation
|
% 0.01
|
|||||||||||
Overload protections (0.8 PF)
|
up to 115% for Continuous, 115%-125% for 10 min, 125%-150% for 1 min, 150%-168% for 5 sec
|
|||||||||||
BATTERIES
|
||||||||||||
Type
|
VRLA AGM / GEL
|
|||||||||||
Recharge time
|
6 hours
|
|||||||||||
INSTALLATION
|
||||||||||||
Weight without batteries
|
105
|
110
|
115
|
115
|
135
|
145
|
190
|
200
|
370
|
380
|
450
|
460
|
Dimensions (mm) HxWxD
|
1320x440x850
|
1320x440x850
|
1600x500x850
|
1900x750x855
|
1900x850x1050
|
|||||||
Communication
|
3 sockets for Communication interface/RS232/USB
|
|||||||||||
Temperature range
|
0ºC / +40ºC
|
|||||||||||
Humidity
|
%90 non-condensed
|
|||||||||||
Colour
|
Dark grey RAL 7016
|
|||||||||||
Acoustic noise (1m)
|
< 52 dBA
|
< 48 dBA
|
< 52 dBA
|
< 65 dBA
|
< 50 dBA
|
|||||||
Protection degree
|
IP20
|
|||||||||||
Efficiency
|
up to % 99
|
|||||||||||
Standards
|
Directive EMC 2004 / 108 / CE Electromagnetic Compability Directive
|
|||||||||||
Standards : Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2
|
||||||||||||
in accordance with IEC EN 62040-3 ( Voltage and Frequency Independent) VFI-SS-111
|