Hãng sản xuất | Megatech |
Xuất xứ | Ấn Độ |
Model | MPS ERD-I |
Rating | Suitable for motors up to 10KW** |
AC INPUT | 415V + 15% -20% Three Phase Four wire |
Frequency | 50Hz ± 6% |
Batteries | 12V, 7AH x 6 nos VRLA Batteries |
Charging Time | 10 Hours for full Capacity |
Charger Type | CVCC Internal SMPS type |
Technology | IGBT/MOSFET |
Output Voltage | 400 / 415V AC Three Phase |
Frequency | 50Hz ± 0.05Hz |
Waveform | PWM Sine wave |
Harmonic Distortion | Less than 3% on Linear Load |
Inverter Efficiency | >85% |
Power Factor | 0.8 |
Crest Factor | 3:1 |
Phase Displacement | 1200 ± 10 |
Audible Noise | Less than 50 dB at 1 Meter |
GENERAL: | |
Dimensions (LxWxH)mm | 640x 240x600 |
Operating temperature | 00C to 500C |
Humidity | Max 95%, Non-condensing |
PROTECTIONS : | |
Output Overload & Short circuit, Output Under & Overvoltage, Batt Low | |
INDICATIONS & ALARMS: | |
a) Mains on | Indication |
b) Inverter on | Indication |
c) DC Low | Indication & Alarm |
d) Fault | Indication & Alarm |
CHANGE-OVER | |
a) Electro mechanical switch Internal for single lift, External for Multiple Lifts | |
** For ERD-1 the Lift should be equipped with VVVF drive suitable to operate in Low power mode during power failure till nearest floor and should be interfaced with the ERD for RUN and STOP operation | |
* Specifications are subject to change without prior notice due to constant improvement in design & technology |
Model | MPS ERD-I |
Rating | Suitable for motors up to 10KW** |
AC INPUT | 415V + 15% -20% Three Phase Four wire |
Frequency | 50Hz ± 6% |
Batteries | 12V, 7AH x 6 nos VRLA Batteries |
Charging Time | 10 Hours for full Capacity |
Charger Type | CVCC Internal SMPS type |
Technology | IGBT/MOSFET |
Output Voltage | 400 / 415V AC Three Phase |
Frequency | 50Hz ± 0.05Hz |
Waveform | PWM Sine wave |
Harmonic Distortion | Less than 3% on Linear Load |
Inverter Efficiency | >85% |
Power Factor | 0.8 |
Crest Factor | 3:1 |
Phase Displacement | 1200 ± 10 |
Audible Noise | Less than 50 dB at 1 Meter |
GENERAL: | |
Dimensions (LxWxH)mm | 640x 240x600 |
Operating temperature | 00C to 500C |
Humidity | Max 95%, Non-condensing |
PROTECTIONS : | |
Output Overload & Short circuit, Output Under & Overvoltage, Batt Low | |
INDICATIONS & ALARMS: | |
a) Mains on | Indication |
b) Inverter on | Indication |
c) DC Low | Indication & Alarm |
d) Fault | Indication & Alarm |
CHANGE-OVER | |
a) Electro mechanical switch Internal for single lift, External for Multiple Lifts | |
** For ERD-1 the Lift should be equipped with VVVF drive suitable to operate in Low power mode during power failure till nearest floor and should be interfaced with the ERD for RUN and STOP operation | |
* Specifications are subject to change without prior notice due to constant improvement in design & technology |