AS-i 3.0 from ID no. 12003 (see lateral Label) 

1 AS-i master
PROFIBUS slave

 

Recognition of duplicate AS-i addresses

 

AS-i Earth Fault Detector integrated

 

AS-i Noise Detector integrated



 

 

 


Art. no.

BWU1567

 

Art. no.

BW1653

Class 1 Div. 2 
(Group A, B, C & D, T-Code 4)

BWU1773

           BWU1703

AS-i 3.0 from ID no. 12470, without RS232
diagnosis interface, without recognition of
duplicate AS-i addresses

Operating current

master power supply
approx. 200 mA out of AS-i circuit

Operating voltage

AS-i voltage 30 V DC

PROFIBUS interface

according to DIN 19 245 Part 3

Serial interface

RS 232

-

Baud rates

9,6 KBaud up to 12000 KBaud, automatic recognition

DP functions

imaging of the AS-i slaves as I/O Data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP

AS-i cycle time

150 μs*(number of slaves + 2)

Displays

 

LCD

displaying slave addresses and error messages

LED green (power)

power on

LED green (PROFIBUS)

PROFIBUS master recognized

LED red (config error)

configuration error

LED green (U AS-i)

AS-i voltage OK

LED green (AS-i active)

AS-i normal operation active

LED green (prg enable)

automatic address programming enabled

LED yellow (prj mode)

master is in configuration mode

Buttons

4

Voltage of insulation

≥ 500 V

EMC directions

EN 61 000-6-2, EN 61 000-6-4

Operating temperature

0°C ... +55°C

Storage temperature

-25°C ... +85°C

Housing

AS-i master housing in stainless steel

Dimensions (L, W, H in mm)

120 / 75 / 83

Protection category (DIN 40 050)

IP20

Tolerable loading reffering to impacts and vibrations

according to EN 61 131-2

Weight

460 g






 


Art. no.

BWU1568

 

 

Art. no.

 

BW1654

Class 1 Div. 2 
(Group A, B, C & D,
T-Code 4)

BWU1774

AS-i 3.0 from ID no. 12470,
without RS232 diagnosis
interface, without recognition
of duplicate AS-i addresses

Operating current

master power supply,
max. 200 mA out of AS-i circuit 1
(approx. 70 mA ... 200 mA),
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 200 mA);
in sum max. 270 mA

approx. 200 mA out of AS-i circuit 1
approx. 70 mA out of AS-i circuit 2

PROFIBUS interface

according to DIN 19 245 part 1-3

Serial interface

RS 232

-

Baud rates

9,6 KBaud up to 12 000 KBaud, automatic recognition

DP functions

imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP

AS-i cycle time

150 μs*(number of slaves + 2)

Displays

 

LCD

displaying slave addresses and error messages

LED green (power)

power on

LED green (PROFIBUS)

PROFIBUS master recognized

LED red (config error)

configuration error

LED green (U AS-i)

AS-i voltage OK

LED green (AS-i active)

AS-i normal operation active

LED green (prg enable)

automatic address programming enabled

LED yellow (prj mode)

master is in configuration mode

Buttons

4

Voltage of insulation

≥ 500 V

EMC directions

EN 61 000-6-2, EN 61 000-6-4

Operating temperature

0°C ... +55°C

Storage temperature

-25°C ... +85°C

Housing

AS-i master housing in stainless steel

Dimensions (L, W, H in mm)

120 / 75 / 83

Protection category 
(DIN 40 050)

IP20

Weight

460 g

Accessories:




 



 

AS-i 3.0 from ID no. 12003 (see lateral Label)2 AS-i masters

 

Recognition of duplicate AS-i addresses

 

AS-i Earth Fault Detector integrated

 

AS-i Noise Detector integrated

 

BWU1569 and BW1655 in version 
1 gateway, 1 power supply for 2 AS-i circuits: 
Only 1 gateway + 1 AS-i power supply for 2 AS-i networks



 

 

 


Art. no.

BWU1569

 

Art. no.

BW1655
Class 1 Div. 2 (Group A, B, C & D, T-Code 4)

 

Operating current

version "1 gateway, 1 power supply for 2
AS-i circuits", approx. 250 mA
(PELV voltage)

PROFIBUS interface

according to DIN 19 245 part 1-3

Serial interface

RS 232

Baud rates

9,6 KBaud up to 12000 KBaud, automatic recognition

DP functions

imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP

AS-i cycle time

150 μs*(number of slaves+ 2)

Displays

 

LCD

displaying slave addresses and error messages

LED green (power)

power on

LED green (PROFIBUS)

PROFIBUS master recognized

LED red (config error)

configuration error

LED green (U AS-i)

AS-i voltage OK

LED green (AS-i active)

AS-i normal operation active

LED green (prg enable)

automatic address programming enabled

LED yellow (prj mode)

master is in configuration mode

Buttons

4

Voltage of insulation

≥ 500 V

EMC directions

EN 61 000-6-2, EN 61 000-6-4

Operating temperature

0°C ... +55°C

Storage temperature

-25°C ... +85°C

Housing

AS-i master housing in stainless steel

Dimensions (L, W, H in mm)

120 / 75 / 83

Protection category (DIN 40 050)

IP20

Weight

460 g

 

Accessories:



 





Art. no.

BWU1746

Operating current

master power supply
approx. 200 mA out of AS-i circuit (max. 300 mA)

Operating voltage

AS-i voltage 30 V DC

PROFIBUS interface

according to DIN 19 245 part 3

Baud rates

9,6 KBaud up to 12 000 KBaud, automatic recognition

DP functions

imaging of the AS-i slaves as I/O Data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP

AS-i cycle time

150 μs*(number of slaves + 2)

Displays

 

LED

displaying slave addresses and error messages

LED green (power)

power on

LED green (PROFIBUS)

PROFIBUS master recognized

LED red (config error)

configuration error

LED green (U AS-i)

AS-i voltage OK

LED green (AS-i active)

AS-i normal operation active

LED green (prg enable)

automatic address programming enabled

LED yellow (prj mode)

master is in configuration mode

Buttons

2

Voltage of insulation

≥ 500 V

EMC directions

EN 61 000-6-2, EN 61 000-6-4

Operating temperature

0°C ... +55°C

Storage temperature

-25°C ... +85°C

Housing

AS-i master housing in stainless steel

Dimensions (L, W, H in mm)

120 / 45 / 40

Protection category (DIN 40 050)

IP20

Tolerable loading reffering to impacts and vibrations

according to EN 61 131-2

Weight

300 g


 

Accessories:


PROFIBUS DP Gateway/Link 
with decoupling coils

 

1 AS-i-Master
PROFIBUS-Slave

 

Duplicate address'' recognition

AS-i earth fault detector integrated

 

AS-i noise detector integrated


 

 

 



Graphical display

Art. no. BWU1891