CO 100
CO detector
CO detection. Displaying of ambient temperature. Two adjustable alarm tresholds. COmax display.
Technical data
- CO : from 0 to 500 ppm
- Temperature : from -20 to +80°C
|
CT 100
Optical (O) contact (C)
Functions : optical or contact tachometry
Measuring range : CT 100 O
- From 60 to 60 000 tr/min
Supplied with optical probe, transport case and calibration certificate.
CT 100 C
- From 30 to 20 000 tr/min
Supplied with optical probe and ETC adaptor, transport case and calibration certificate.
|
HD 100
Hygrometer
Functions : Relative humidity, dew point and temperature.
Measuring range
- Humidity : 5 to 95 %HR
- Temperature : -20 to +80°C
- Dew point : -40 to +80°Ctd
Supplied with hygrometrie probe, transport case and calibration certificat |
HD 150
Special food industry
Relative humidity, dew point and temperature. HACCP principle.
Measuring range
- Humidity : 5 à 95 %RH
- Temperature : -20 to +80°C
- Dew point : -40 to +80°Ctd
Supplied with hygrometry probe, transport case and calibration certificate. |
HM 100
Pin moisture meter
Humidity percentage measure of wood, concrete, plaster and bricks.
Measuring range
- Softwood : from 10 to 93.7 %
- Harwood : from 8 to 78.5 %
- Concrete and plaster : from 1 to 2.5 %
- Bricks : from 0 to 22.9 %
Supplied with a protection cap, transport case, 2 sets of pins and a fitting certificate. |
LV 100
LV 101 - LV 107 - LV 110Functions : Vane velocyti and airflow, temperature.
Technical dataLV 101 - Ø 14 mm vane
- Air velocity : 0,8 to 25 m/s
- Temperature : -20 to +80°C
- Air flow : 0 to 99999 m³/h
LV 107- Ø 70 mm vane
- Air velocity : 0,3 to 35 m/s
- Temperature : -20 to80°C
LV 110- Ø 110 mm vane
- Air velocity : 0,25 to 35 m/s
- Air flow : 0 to 99999 m³/h
- Temperature : -20 to +80°C
Supplied with vane, transport case and calibration certificate. |
LV 130
Vane probe thermo-anemometerØ 100 mm vane probe. Functions : air velocity, airflow, ambient temperature.
2 models
- LV 130 : rotating vane probe
- LV 120 : fixed vane probe
Measuring range
- Air velocity : from 0.25 to 35 m/s
- Airflow : from 0 to 99.999 m3/h
- Temperature : from 0 to +50°C
Supplied with transport case and calibration certificate. |
MP 100
MP 101 - MP 105 - MP 112 & MP 120Functions : Pressure, differential pressure, manual autocalibration, Hold function, min/max. values.
Measuring rangeMP 100 : 0 to ±1000 Pa MP 101 : 0 to ±1000 mmH2O MP 105 : 0 to ±500 mBar MP 112 : 0 to ±2000 mBar MP 120 : 0 to ±1000 Pa and from 2 to 40 m/s
Supplied with calibration certificate and transport case. |
Bình luận