| Type | NPN input | PNP input | |
| Model No. | FX-CH | FX-CH-P | |
| Applicable sensors | FX-301B/G/H(P), LS-401(P) | ||
| Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | ||
| Current consumption | 25 mA or less (When all indicators light up) | ||
| Bank selection input | Low: 0 to 2 V DC (Source current: 0.5 mA Input impedance: 10 kΩ approx.) High: 5 V to +V DC, or open |
High: 4 V to +V DC (Sink current: 0.5 to 3 mA Input impedance: 10 kΩ approx.) Low: 0 to 0.6 V DC, or open |
|
| Power indicator | Green LED (Lights up when the power is ON) | ||
| Transmission operation indicator | Green LED (Lights up when loaded, blinks → lights up when saved) |
||
| Pollution degree | 3 (Industrial environment) | ||
| Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
||
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||
| EMC | EN 61000-6-2, EN 61000-6-4 | ||
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||
| Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | ||
| Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | ||
| Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each | ||
| Material | Enclosure: Heat-resistant ABS | ||
| Connecting method | Connector (Note 2) | ||
| Cable length | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | ||
| Weight | Net weight: 20 g approx., Gross weight: 25 g approx. | ||
| Dimensions | W10 x H27 x D64.5 mm W0.394 x H1.063 x D2.539 in | ||
| Accessory | SL-CP1 (4-pin type snap male connector): 1 pc. | ||