Liên hệ
D3, Kdc Miếu Nổi, Đinh Tiên Hoàng, P.3, Q.bình Thạnh
Hãy liên hệ trực tiếp với chúng tôi
CÔNG TY TNHH THƯƠNG MẠI DỊCH VỤ ANH NGHI SƠN
Lương Vi Thành (Mr.)
| Senior Sales Eng . |
=================================
| Cellphone | +84 1693 630 777
| Email | thanh.ans@ansvietnam.com
========== Online contact ============
| Yahoo | thanh_ans | Skype | vithanh_ans
để được hỗ trợ TỐT NHẤT với thời gian NHANH NHẤT !
******
Công ty chúng tôi xin gửi đến Quý khách hàng thông tin của Model sản phẩm như sau:
Thiết bị đo độ ẩm vải Model TEM Series |
Thiết bị đo độ ẩm vải Model DHT Series |
Một số Model thông dụng:
Moisture meter |
| |||||
Model | Description | |||||
TEM I | Consisting of basic type TEM with analog display, measuring cable 50200M, electrode holder | |||||
50204M, needle electrodes 50205M and 50207M | ||||||
TEM | Base type TEM with carrying case, without attachments | |||||
Test Report: | Test report of the manufacturer for new instruments |
| ||||
1) Accessoires and Spare parts: |
| |||||
50200M | Measuring cable (200) |
| ||||
50204M | Electrode holder (204) |
| ||||
50202M | Cup electrode (202) | 140 x 63 mm Ø for cotton | ||||
50205M | Needle electrode (205) | needle length 25 mm | ||||
50206M | Needle electrode (206) | needle length 45 mm | ||||
50207M | Needle electrode (207) | needle length 100 mm | ||||
50208M | Needle electrode (208) | needle length 17 mm | ||||
50209AM | Stab electrode (209A) | needle length 325 mm | ||||
50209BSM | Cotton electrode (209 BSM) | needle length 75 mm for pressed cotton | ||||
50210M | Knife electrode (210) | knife length 110 mm | ||||
50211M | Roller electrode (211) | roller diameter 27 mm | ||||
50212M | Continuous run electrode (212) | roller diameter 16 mm | ||||
50213M | Surface electrode (213) | surface diameter 23 mm | ||||
50299M | Calibration electrode (299) | with a fixed calibration value | ||||
Model | Description | |||||
DHT-1 | Consisting of basic type DHT with digital display, measuring cable 50400M, electrode holder 50404M, needle electrodes 50414M and 50418M | |||||
Test Report: | Test report of the italian calibration labatory |
| ||||
1) Accessoires and Spare parts: |
|
| ||||
50400M | Measuring cable | |||||
50404M | Electrode holder | |||||
50428M | Thermo- Hygromertric probe (temperature and humidity probe) | |||||
50412M | Needle electrode | needle length 300 mm | ||||
50418M | Needle electrode | needle length 60 mm | ||||
50414M | Needle electrode | needle length 100 mm | ||||
50416M | Roller electrode | roller diameter 27 mm | ||||
50422M | Calibration electrode - 2 pcs | with different calibration value | ||||
Leak-Detect |
| |||||
Model | Air-Leakage instrument | |||||
LDT-1 | Basic unit LDT with probe, detector and ear-phones |
| ||||
LDT-2 | same as model LDT-1, but additional with attachment 55001H, 55002H, 55003H, 55004H |
| ||||
Test Report: | Test report of the manufacturer for new instruments | free of charge |
| |||
Test report of the manufacturer (for calibration of used instrument) |
|
| ||||
1) Attachments: |
|
| ||||
55001H | Extended Probe ( 260 mm gooseneck) |
| ||||
55002H | Telescope for long distance detection (1,6 m - 3 m, with handle, spiral cable and integrated probe) |
| ||||
55003H | Ultrasonic-transmitter for leakage check of cabins or other closed casings |
| ||||
55004H | Accu recharger 230 V AC , 50/60 Hz incl. 9 V battery |
| ||||
55005H | Short Probe (85 mm gooseneck) |
| ||||
55006H | Ultrasonic parabolic reflector with laser pointer |
| ||||
Softometer |
|
|
| |||
Model | Measuring Range | Resolution | ||||
KWS-500 | 0 - 500 mN | 0.5 mN |
| |||
KWS-2000 | 0 - 2000 mN | 1 mN |
| |||
KWS-20K | 0 - 20 N | 10 mN |
| |||
Test Report: | Test report of the manufacturer |
|
| |||
1) Attachments: |
|
| ||||
99901W | Calibration Standard 80 - 85 mN |
| ||||
99902W | Calibration Standard 240 - 245 mN |
| ||||
99903W | Calibration Standard 385 - 390 mN |
| ||||
99904W | Calibration Standard 635 - 640 mN |
| ||||
Repairs and services charges | ||||||
Repair costs are calculated on a time and material basis. If the costs are lower than 40% of the new price of the device, the repair is made without customer’s approval. If costs are higher, a cost estimation will be made. | ||||||
If customer orders cost estimation, he will be charged 25,- EUR. | ||||||
If the customer rejects the cost estimation and the device is sent back without repair, he will be charged a flat rate of 50,- EUR | ||||||
plus all additional charges that may (delivery, customs etc.) occur . These costs will not be charged if a new device is ordered instead. | ||||||
Readjustment of used instruments: Adjustment and checking of used instruments | ||||||
Test reports and calibration certificates for new instruments | ||||||
Force gauges: Tensile test | ||||||
Calibration certificate with calibration report included for force gauges up to 1000 N (only one direction of force - tension force) | ||||||
Calibration certificate with calibration report included for force gauges up to 5000 N (tension or compression force; by external laboratory) | ||||||
Calibration certificate with calibration report included for load cells with external measuring amplifier up to 20 kN (tension or compression force; by external laboratory) | ||||||
Torque meters: Clockwise and counterclockwise | ||||||
Calibration certificate with calibration report included (for torque meters) | ||||||
Tachometers (with Checking device Model ES 2 B, DKD-Admittance No. 1.43-292-56/74 up to 5000 rpm) | ||||||
Calibration certificate with calibration report included (for tachometers) | ||||||
Stroboscopes (with Checking device Model ES 2 B, DKD-Admittance No. 1.43-292-56/74 up to 20000 rpm) | ||||||
Calibration certificate with calibration report included (for Stroboscopes - NOT LED Stroboscopes) | ||||||
Calibration certificate with calibration report included (for LED Stroboscopes) | ||||||
Thickness Gauge | ||||||
Test report of manufacturer - please find information on page 13 and 14 of price list for series J, K, F | ||||||
Calibration certificate done by an DKD approved laboratory for new gauge series D-2000, D-2010 and D-2020 | ||||||
Hardness testers (Durometer for Shore-Hardness or Textile Hardness tests) | ||||||
Calibration certificate with calibration report included (for Hardness testers) | ||||||
Textile Moisture Meter | ||||||
Calibration certificate with calibration report included (for textile moisture meters) | ||||||
Test reports and calibration certificates for used instruments (or in-use instruments) | ||||||
can be made only for instruments which are supplied by Hans Schmidt & Co; if adustment is necessary, this will be charged extra | ||||||
Force gauges | ||||||
Calibration certificate with calibration report included for used force gauges up to 1000 N (only one direction of force - tension force) | ||||||
Calibration certificate with calibration report included for used force gauges up to 5000 N (tension or compression force; by external laboratory) | ||||||
Calibration certificate with calibration report included for used load cells with measuring amplifier up to 20 kN (tension or compression force; by external laboratory) | ||||||
Torque meters: clockwise and counterclockwise | ||||||
Calibration certificate with calibration report included (for used torque meters) | ||||||
Tachometers (with Checking device Model ES 2 B, DKD-Admittance No. 1.43-292-56/74 up to 5000 rpm) | ||||||
Calibration certificate with calibration report included (for used tachometers) | ||||||
Stroboscopes (with Checking device Model ES 2 B, DKD-Admittance No. 1.43-292-56/74 up to 20000 rpm) | ||||||
Calibration certificate with calibration report included (for used Stroboscopes - NOT LED Stroboscopes) | ||||||
Calibration certificate with calibration report included (for used LED Stroboscopes) | ||||||
|
|
| ||||
Thickness Gauge | ||||||
Test report of manufacturer - for used thickness gauges series J-40 | ||||||
Calibration certificate done by an DKD approved laboratory for used gauge (only available for series D-2000, D-2010 and D-2020) | ||||||
Hardness testers (Durometer for Shore-Hardness or Textile Hardness tests) | ||||||
Calibration certificate with calibration report included (for used Hardness testers) | ||||||
Textile Moisture Meter | ||||||
Calibration certificate with calibration report included (for used textile moisture meters) |
HẾT HẠN
Mã số : | 10932057 |
Địa điểm : | Hồ Chí Minh |
Hình thức : | Cần bán |
Tình trạng : | Hàng mới |
Hết hạn : | 27/12/2020 |
Loại tin : | Thường |
Gợi ý cho bạn
Bình luận