Transmission rate | |
Transfer rate | |
| 9.6 kbit/s…12 Mbit/s |
| 45.45 kbit/s |
Interfaces | |
Number of electrical/optical connections / for network components or terminal equipment / maximum | 3 |
Number of electrical connections | |
- for network components and terminal equipment
| 1 |
| 1 1 |
| 1 |
| 1 |
- for redundant power supply
| 1 |
Design of electrical connection | |
- for network components and terminal equipment
| 9-pin Sub-D socket |
| 2-pole terminal block |
- for power supply and signaling contact
| 5-pole terminal block |
Number of optical interfaces / for optical waveguide | 2 |
Design of the optical interface / for optical waveguide | BFOC port |
Optical data | |
Damping ratio / of FOC transmission link | |
- for glass FOC with 50/125 µm / at 3 dB/km / maximum
| 10 dB |
- for glass FOC with 62.5/125 µm
| |
| 12 dB |
Signal delay time in bit time | 6.5 bit |
Injectable optical power relating to 1 mW | |
- for glass FOC with 50/125 µm / at 3 dB/km
| -16 dB |
- for glass FOC with 62.5/125 µm
| |
| -13 dB |
Optical sensitivity relating to 1 mW | |
- for glass FOC with 50/125 µm / at 3 dB/km
| -28 dB |
- for glass FOC with 62.5/125 µm
| |
| -28 dB |
Wavelength | |
- for glass FOC with 50/125 µm / compatible with interface / at 3 dB/km
| 860 nm |
- for glass FOC with 62.5/125 µm / compatible with interface
| |
| 860 nm |
Cable length | |
- for glass FOC with 50/125 µm / at 3 dB/km / maximum
| 3 km |
- for glass FOC with 62.5/125 µm at 3.5 dB/km maximum
| |
| 3 km |
Signal-Inputs/outputs | |
Operating voltage / of signaling contacts / at DC / rated value | 24 V |
Operating current / of signaling contacts / at DC / maximum | 0.1 A |
Supply voltage, current consumption, power loss | |
Type of / supply voltage | DC |
Supply voltage / for DC | |
| 24 V |
| 18.8 V |
| 28.8 V |
Product component / fusing at power supply input | Yes |
Consumed current / At 24 V / with DC / maximum | 0.2 A |
Permitted ambient conditions | |
Ambient temperature | |
| 0…60 °C |
| -40…+70 °C |
| -40…+70 °C |
Relative humidity | |
- at 25 °C / without condensation / during operating / maximum
| 95 % |
Protection class IP | IP40 |
Design, dimensions and weight | |
Design | compact |
Width | 39.5 mm |
Height | 112 mm |
Depth | 74.5 mm |
Net weight | 340 g |
Mounting type | |
| Yes |
| Yes |
Product properties, functions, components / general | |
Product function / Ring redundancy | Yes |
Standards, specifications, approvals | |
Standard | |
| FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
| EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X |
- for safety / of CSA and UL
| UL 60950-1, CSA C22.2 Nr. 60950-1 |
- for hazardous area / of CSA and UL
| UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
| EN 61000-6-4 (Class A) |
- for interference immunity
| EN 61000-6-2 |
Verification of suitability | EN 61000-6-2, EN 61000-6-4 |
| Yes |
| Yes |
Marine classification association | |
- American Bureau of Shipping Europe Ltd. (ABS)
| Yes |
| Yes |
| Yes |
| Yes |
- Lloyds Register of Shipping (LRS)
| Yes |
| Yes |
Bình luận